E3 Inspection Reporting
What an E3 report looks like
An excerpt from a real SB 721 inspection report produced by an E3 Inspection Association member using the E3 Mobile App and E3 Web. The cover page and one inspected element are shown.
On-screen sample only. Property details have been removed and the report is shown for viewing, not download. On a member’s actual report the logo, header and footer carry that member’s own company branding; the Association mark is shown here in its place. A complete sample report can be requested from the Association.
E3 Inspection Association Member
Visual Inspection Report
| Project Name: | Sample Apartments (name withheld) |
| Project Address: | Los Angeles County, CA |
| Project Description: | Created from accepted proposal |
| Created Date: | 10/14/2026 |
| Created By: | E3 Inspection Association Member |
| Report Type: | Health & Safety Code § 17973 (SB 721) — Exterior Elevated Elements |
E3 Certified InspectorReport produced with the E3 Mobile App & E3 Web · E3 Inspection Association
· · · scope, definitions and repair notations omitted from this sample · · ·
E3 Inspection Association Member
| Visual Inspection Details | |
| Project Common Name | Building A — Unit 2 Balcony |
| Section Name | Balcony, Soffit and Railing |
| Visual Report | |
| Exterior Elements | Balcony Deck, Soffit, Railings, Door Threshold, Stucco / Siding Interface |
| Water Proofing Elements | Flashings, Waterproofing, Coatings, Sealants |
| Visual Review | Fair |
| Any Visual Signs of leaks | Yes |
| Further Invasive Review Required | Yes |
| Condition Assessment | Repair Recommended |
| Additional Considerations or Concerns | Soffit cladding is separated and stained along the outer deck edge, indicating water intrusion behind the edge flashing. Remove soffit panel to inspect joist ends and ledger; repair flashing and re-seal before the next wet season. |
| Life Expectancy (EEE) | 1-4 Years |
| Life Expectancy (LBC) | 0-1 Years |
| Life Expectancy (AWE) | 0-1 Years |
| Visual Photos | |



E3 Certified InspectorReport produced with the E3 Mobile App & E3 Web · E3 Inspection Association
· · · remaining elements, photo log and conclusions omitted from this sample · · ·
About the E3 Mobile App
Request a complete sample report
Request a complete sample report
Reports produced with E3 carry the inspecting member’s own logo, header and footer. This excerpt shows the Association’s mark in their place.